Traceify and hosted sites outage, 25 to 26 November 2026
Sites hosted on Stratware Labs were offline on 26 November from 02:52 to 20:14 CET, about 17 and a half hours. traceify.win was offline longer, from 21:17 CET on 25 November, about 23 hours. Everything is back, and no stored data was lost.
Timeline
All times are CET.
| When | What happened |
|---|---|
| 25 Nov, 21:17 | traceify.win starts failing with "502 Bad Gateway" after a network setting changed on the server. |
| 26 Nov, 02:52 | The service that runs hosted sites runs out of memory and stops. Every hosted site goes offline. |
| 26 Nov, 02:52 | The service restarts by itself, but the sites cannot start again. The Traceify database restarts and recovers by itself. |
| 26 Nov, about 20:05 | The outage is found when traceify.win does not load. No alert had fired. |
| 26 Nov, 20:10 | traceify.win traffic is routed correctly again. |
| 26 Nov, 20:12 | The leftover processes are stopped cleanly and every hosted site is started again. |
| 26 Nov, 20:14 | Routing to every site is rebuilt. All sites answer normally. |
What happened
Two separate problems overlapped.
- traceify.win was sent to the wrong place. On 25 November we added a private address for our own test environment on the same server. That setting also caught the traffic for traceify.win and answered it with the wrong certificate. The server forwarding traceify.win rejected that answer, which is the right, safe behaviour, so visitors saw "502 Bad Gateway".
- The service that runs hosted sites ran out of memory. At 02:52 on 26 November the system stopped it to protect the rest of the server. It restarted within seconds, but parts of the old run were still in place, and they blocked every site from starting again. The sites stayed down until someone stepped in.
We fixed the first by giving traceify.win its own entry on that address. We fixed the second by stopping the leftovers cleanly, the database last with a proper shutdown, then starting every site and rebuilding the routing to them.
Why you don't need to worry
- Your stored data is safe. One database was shut down properly before it started again. The other was stopped suddenly, then replayed its own log on restart and came back complete. That is what databases are built to do after a sudden stop.
- This was not a security incident. The cause was memory on our server and a setting of ours, not an attack.
- Nothing changed in your sites. Code, files, settings and addresses are as they were.
- You don't need to do anything. Everything is running again as before.
One thing to know: anything sent to a site while it was offline, such as a form or a message to a bot, never arrived, so it was not saved. If you sent something important in that window, please send it again.
What we are changing
- An alert when a hosted site stops answering, so an outage is found in minutes, not hours.
- Automatic recovery when the service that runs sites restarts, including clearing what an old run leaves behind.
- Routing that comes back complete on its own after a restart.
- A look at why the service grew until it ran out of memory, and a fix for it.
- A check of the forwarding for traceify.win whenever server network settings change.